Guidelines for usage of air insulated substation ais or gas. Distribution substations michigan technological university. Experimental study of fast transient currents in gas. Since 1974 we have supplied gas insulated substations. In order to enhance the protection of current transformers in high voltage gas insulated switchgears, the invention is, that the current transformer is formed andor embedded by vacuum. Jan 02, 2019 in this gis or gas insulated switchgear system than one functional element are encapsulate in a single metal enclosure. Gas insulated substations are used where there is space for providing the substation is expensive in large cities and towns 21. A gas insulated substation gis uses a superior dielectric gas, sf6, at moderate pressure for phasetophase and phasetoground insulation. Over the last 30 years, gas insulated switchgear gis has been used for a wide range f application. A gas tight barrier insulator in switchgear serve for the separation of gas compartments and prevents neighbouring switchgear parts from being affected during maintenance.
Electromagnetic disturbances of the secondary circuits in gas insulated substation due to disconnector switching ivo uglesic1, sandra hutter1, viktor milardic1. A switchgear may be a simple openair isolator switch or it may be insulated by some other substance. Which is the first equipment seen in the substation while coming from transmission system a circuit breaker b lightning arrester c current transformer d transformer. Similar to ais substations gis installation includes voltage transformers to decrease the bus. Pdf methods that have been used to evaluate the performance of uhf couplers for partial discharge monitoring of gas insulated substations are briefly. Gis there are two terms presented in iec gas insulated switchgear and ieee gas insulated substations. The thermal currentcarrying capacities and the faultwithstanding capabilities are tailored to meet all the substation requirements. An electrical substation is an installation with electrical equipment capable of interrupting or establishing electrical circuits and changing the voltage, frequency, or other characteristics of the electrical energy flowing in the circuits. Wo2017102983a1 current transformer for high voltage gas. An effective although more costly form of switchgear is the gas insulated switchgear gis, where the conductors and contacts are insulated by pressurized sulfur hexafluoride gas sf 6. A small switching station may be little more than a bus plus some circuit breakers. The thermal current carrying capacities and the faultwithstanding capabilities are tailored to meet all the substation requirements.
Each distribution voltage the substation supplies must have its own bus. The siemens gas insulated switchgear gis is an extremely successful product concept. This conference will address regulatory, technical and business considerations for gis. The clearance required for phase to phase and phase to ground for all equipment is much lower than that required in an air insulated substation. Distribution substation a distribution substation transfers power from the transmission system to the distribution system of an area.
Gasinsulated switchgear up to 550 kv, 63 ka, 5000 a type. Major components you can spot while looking at mvhv gis gas insulated switchgear gis are available internationally, covering the complete voltage range from 11 kv to 800 kv. Hv ct are commonly installed outdoors, in ais substations air insulated substation figure 2 or indoors, in gis substations gas insulated substation figure 3. Mv ct are usually installed indoors, in mv switchgears figure 4. A gas insulated substation gis is a high voltage substation in which the major structures are contained in a sealed environment with sulfur hexafluoride gas as the insulating medium. The report gas insulated transformer market by type instrument transformer, others, voltage medium voltage, high voltage, extra high voltage, installation outdoor, indoor, enduser utility, industrial, commercial, and region global forecast to 2023, the gas insulated transformer market is expected to grow from usd 2. Gis gas insulated switchgear power transformer, gis. Pdf analysis and calculation of very fast transient over voltages. Gasinsulated metalenclosed switchgear for rated voltages above 52 kv 092011 orequired leakage rate nov 04, 2017 gas insulated substations gis differ from air insulated substations substations we usually see such that all the substation equipment such as busbars, circuit breakers, current transformer, potential transformers and other substation equipment are placed inside sf6 modules filled with sf6 gas. Elk cn3 current transformer installation in a separate manual available upon request. Tg gas insulated high voltage current transformers 72. Ct used for the measurement of ac current by taking the samples of higher currents of the system.
The portfolio includes gis solutions from 60 to 800 kv, along with secondary products to maximize switchgear and network operation. Current transformer, voltage transformers, gis, tank. Gas insulated substations use sulphur hexa fluoridesf6 gas which has superior dielectric properties. Gis gas insulated switchgear power transformer, gis, gcb. Other common types are oil or vacuum insulated switchgear. Xdge provides gas insulated switchgear gis solutions for high to ultra. Siemens transmission products presentation digital asset.
Tranformers, gas insulated switchgears, circuit breakers, surge arresters, disconnectors, instrument transformers, and bushings. The possibility of a subtransmission circuit fault is much higher than a transformer fault. Request pdf experimental study of fast transient currents in gas insulated substation the increasing demand in transmitting electrical energy at very high voltages with low transmission losses. Current transformers are designed to provide a scaled down replica of the current in the hv line and isolate the measuring instruments, meters, relays, etc.
The input for a distribution substation is typically at least two transmission or subtransmission lines. Elk cn14560 current transformer for gas insulated switchgear. Gas insulated substation electrical substation transformer. Development of 22kv distribution systems and switchgear. Often, building new substations or increasing capacity is difficult because land is either not available or is prohibitively expensive. Current, voltage and combined transformers, oilpaper or gas insulated up to 800 kv. Current transformers are typically installed in the circuit breaker bushing turrets. Gas insulated substation gis also called sf6 gas insulated metalclad switchgear is preferred for 12kv, 36kv, 72. With gis experience spanning 50 years across a wide range of industries and applications, ge is a leader in the. Siemens provides a wide range of services including the supply of complete packages of highvoltage. In a gis substation, the various equipment like circuit breakers, bus bars, isolators, load break switches, current transformers, voltage transformers, earthing switches, etc.
Gas insulated instrument transformer for enhanced safety and reliability. Voltage transformers f gas insulated bus duct section between gis and xlpe cableoverhead conductor. Typically, they do not have big interrupting capability except for small quantities of charging current associated with short pieces of bus. To prevent moisture, the ring types have epoxyfiberglass applied. Secocue 36v gas insulated medium voltage switchgear secocube is an indoor, factoryassembled, metalenclosed, cubicle type gas insulated switchgear for single busbar applications. Current transformer is an instrument transformer used in substation for measurement and protection purposes. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in sf6 gas inside grounded metal enclosures. Though, both have some properties which differs each other.
Tg is a gas insulated high voltage current transformer based on a topcore design, able to withstand current up to 4,000 a and designed for voltages from 72. Development of 22 kv distribution systems and switchgear 160 conductor for connecting to the cable head at the bottom of the molded case, a current transformer for metering that is built into the epoxy molded insulated housing, a condenser for voltage detection, and three for three phases fourposition vacuum switches. Elk cn31080 current transformer for gasinsulated switchgear. They are applied to isolate different elements of the substation, such as circuit breakers, transmission lines, transformer banks, b uses, and voltage transformers. What is the function of the current transformer in a. The gas insulated substations gis technology is a continuous development process involving new materials, technical functionality, manufacturing processes, quality, and reliability improvements. The design of a gis follows the rules of pressure vessel design with the exception of the repetitive pressure test after installation. Electromagnetic disturbances of the secondary circuits in. A study of air insulated substation ais and gas insulated. Gis technology originated in japan, where there was a substantial need to develop technology to make substations as compact as possible. Gas insulated switchgear is used in industrial areas to fulfil highenergy demands by space saving design with a. The transformer may have differential relaying that trips all of the feeder breakers in the event of a fault.
The history of gasinsulated substations think grid. Guide for application of gasinsulated substations gis 1 kv up to 52 kv. Here is a brief history of its development and pioneers. Sub stationsair insulated substations linkedin slideshare. The largest transmission substations can cover a large area several acreshectares with multiple voltage levels, many circuit breakers, and a large amount of protection and control equipment voltage and current transformers, relays and scada systems. As a result, gas insulated transformers, gas insulated shunt reactor, gis and control panels can be installed in the same room, and such installation realizes the fully sf6 gas. Gas insulated metalenclosed switchgear for rated voltages above 52 kv 092011 orequired leakage rate gas compartment tt f th td i 01% t t. Introduction to gas insulated substations switchgears gis. Gasinsulated switchgear up to 245 kv, 50 ka, 4000 a type 8dn9. Elk cn14 current transformer installation in a separate manual available upon request. Pdf the sf6 gas insulated switchgear has increasingly been used for high. Gas insulated substation ppt pdf presentation gas insulated substations gis is a compact,multicomponent assembly enclosed in a ground metallic housing in which the primary insulating medium is compressed sulphur hexafluoride sf6 gas. The gas insulated substation gis represents a key element of high voltage electrical transmission networks thanks to its reliability, low maintenance requirements and compact dimensions. Sf6 gas having high dielectric property acts as insulating medium between.
Iec 62271203 highvoltage switchgear and controlgear part 203. Both current and voltage transformers are used for measuring and protection purposes. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in sf6 gas. This is a significant change in operating the switchgear with circuit breakers, disconnectors, and switches earth. Transmission substations can range from simple to complex.
Siemens is a leading supplier of engineering, equipment, solutions, and services for highvoltage substations, such as air insulated substations, gasinsulated substations, and gasinsulated lines. The invention relates to a current transformer for high voltage gas insulated switchgear substation, wherein the current transformer is arranged in a enclosure of housing, according to the preamble of claim 1. Current transformer the current transformers are of the singlephase inductive type with one or more cores and preferably located on the outgoing side of the circuit breaker. These current transformers have the primary winding connected in series with the conductor carrying the current to be measured or controlled. A major difference between conventional air insulated substations ais and the gas insulated substations gis is that the sf6 gas insulated electrical components are placed within an earthed, pressurized metallic container. This functional specification covers all types of substation with equipment installed for use on 2, 275 and 400 kv 50 hz systems. It is applicable to both openterminal air insulated ais and metalenclosed gas insulated gis substation constructions and covers equipment operated at lower voltages on the same substation site. Major components you can spot while looking at mvhv gis gasinsulated switchgear gis are available internationally, covering the complete voltage range from 11 kv to 800 kv. Distribution voltages are typically medium voltage, between 2. Ges f35 gis is a fieldproven solution with high availability that meets the challenges of networks up to 170 kv for power generation, transmission, distribution, tertiary and heavy industry applications.
Consult abb ags entire tg gasinsulated high voltage current transformers 72. The current transformers are of the singlephase inductive. Gas insulated substation is employed where a where there is less space available b for high altitude substations c in terrain region d all the above. Utilizing both technical presentations and case studies from leading utilities, attendees will be provided with a sound understanding of gis capability as well as realworld. Extreme low emissions protect the environment stateo eart design gas compartment axial direction. Gas insulated substations gis are different from air insulated substations as all the substation equipment such as bus bars, circuit breakers, current transformer, potential transformers and other substation equipment are placed inside the modules filled with sf6 gas. Tg gasinsulated high voltage current transformers 72. Siemens transmission products offers all products of highvoltage substations including bundling and their electrical integration to systems up to 1. National grid substations technical specification ngts 2. Siemens is a leading supplier of engineering, equipment, solutions, and services for highvoltage substations, such as air insulated substations, gas insulated substations, and gas insulated lines.
Ge provides a full range of gas insulated substations gis for utilities and industries worldwide. Since its introduction back in 1968, siemens has installed more than 28,000 indoor and outdoor switchgear bays worldwide, and well over 300,000 bayyears of operation have been recorded. With layout flexibility, the zf8550 gis consists of a circuit breaker. Major components you can spot while looking at hvehv gis. Ideal for installation at metering points due to its very high. Gasinsulated switchgear up to 550 kv, 63 ka, 5000 a type 8dq1.
Technology gas insulated substations wiley online library. What is the function of the current transformer in a substation. The inductance of the bus duct is calculated from the diameters of conductor and. For example, in some design, a three phase circuit breaker, current transformer, earth switches, even other feeder elements are covered together in a single metal capsule.
Gas insulated transformer use sf6 gas as the insulating and cooling medium instead of insulating oil. The ring type current transformer can be used with both threephase commonenclosure and isolated type gis. Factors such as higho immunity against adverse atmospheric conditions, less maintenance, higher reliability or space savings compared with open air substations are main reasons today for a preferable choice of gis installations worldwide. Primarily used in substations located in urban areas including inside buildings, underground due to safety benefits. Gas insulated substations conference 2018 in washington dc.
A typical gas insulated substation is shown in fig. The current transformer is the ring type hyosung maker used for equipment protection. Current transformer 500kv sf 6 current transformer for over a century, utilities around the world have relied on ge to deliver. Basic working operations of both the substations are same. Gas tight barrier insulators ensure that any effect on adjacent substation components is kept to a minimum. Sep 17, 2012 gas insulated substation 10sep12 10 11. Gis highvoltage gas insulated switchgear substations.
1087 1113 799 1384 1644 1436 1313 1007 430 575 1544 1372 1200 606 1082 1408 734 124 1066 534 254 1052 87 225 851 301 371 691 1179 516 386 523 281 1273 1010